We are informing you of a potential concern with a vendor’s product used in our equipment. The potential for failure
exists in Siemens Sirius cable-operated switches type 3SE7141-1EG10 with “Emergency Stop” function. In defective units the switch is no longer able to perform the required switching function when the user “pulls on the cable”.
The problem relates to switches manufactured from November 11 to 25, 2012. There is a risk of damage to property or injury to persons, depending on the specific application in which the cable-operated switch is installed. You should immediately take the following actions in order to minimize the risk of damage or injury:

Check the DATE OF MANUFACTURE on the name plate of the ‘Cable Operated Switch’

  1. Check the date of manufacture on the name plate of the cable-operated switch

Does the nameplate include code’4W7′

Does the nameplate include ‘4W7’?

If YES, go to step 3.

If no, there is no further action required.

Inspecting the internal components.

Remove the switch cover

Check to see if there is a gray-black spring pin in the hole in the deflection unit

Is there a spring pin?

If NO, Call Park Customer Support at 800-785-3391. If YES, Replace cover and return machine to operation.

Last updated: December 2, 2020

Need Some Help?

Contact Park Industries® Customer Service
800-785-3391customerservice@parkindustries.com

ATTENTION

Prior to beginning installation, operation, or maintenance, you are advised to carefully read ALL instruction manuals and ALL safety materials and procedures provided with your equipment.

You are solely liable for the proper operation and maintenance of the equipment.

Park Industries® is not responsible for and expressly disclaims liability for any injuries (including death) or damage to the equipment or any other property as a result of improper operation or maintenance of the equipment, as well as failure to comply with the procedures set forth in the equipment’s instructional manual or any other safety materials and procedures. If you encounter any problems or difficulties, you are strongly encouraged to seek professional assistance.

Safety is our number one concern. Should you have any questions don’t hesitate to call our service team at 800-785-3391.