• Content Type

  • Reset Filters

(81) Results

hyprecision intensifier overstroke troubleshooting chart

  • Service

Intensifier overstroke happens when the piston in the intensifier strokes faster to one or both sides than the output flow of the waterjet pump can support. The maximum intensifier stroke rate is predetermined by the size of the hydraulic pump. The intensifier should not stroke during this time. If the intensifier strokes, it is likely […]

Setting and troubleshooting Hydraulic pump pressures

  • Service

This procedure is an entire over view of the pump hydraulics. It includes several procedures for setting and troubleshooting the hydraulic system. 1) Place the pump in “Cooling Mode”. Hydraulic pump ‘On’, Intensifier ‘OFF’2) Loosen the jam nut.3) Adjust the differential screw until the hydraulic pressure reads 300 psi. 4) Tighten the jam nut. Verify […]

Ultra-compact command- guide and video

  • Programming

Ultra-Compact command will apply predetermined Ramp In and Ramp out feed rate and distance to blade cuts. Ultra-Compact also has a feature to do Tension Band cuts.

Diagnosing hp leak on the nozzle

  • Service

LOWER THE NOZZLE ON TABLE AND OPEN THE JET TO BLEED ANY PRESSURE FROM THE SYSTEM BEFORE WORKING ON THE JET ASSEMBLY FOLLOW LOCK OUT TAG OUT PROCEDURES If you encounter leaking ,shut down the jet (intensifier ) then tighten again . (The idea is to tighten very slowly until the leak stops) You may […]

Repair High-Pressure Swivel – Minor Rebuild

  • Service

How to assemble a High Pressure Swivel 70008044-2 Kit. You will need the following: Large adjustable wrench 1 & 1/8″ open or box end wrench Isopropyl alcohol Lithium grease Blue Goop O-Ring lube O-Ring pick or small flat blade screw driver Seal Removal Tool Bench Vise Hammer Arbor press – if available 0.575″ gauge pin […]

Gear Engagement

  • Service

This document will show you how to correct backlash or gear mesh on Saber, Saberjet, Saberjet XP and Voyager machines.

mini hopper maintenance

  • Service

This document goes through how to clean the abrasive mini hopper. A. Remove garnet line from the mixing chamber and place in a container to catch the garnet that will drain from the abrasive regulator. This line is gravity fed. B. Press Jet Setup Enable button C. Press Garnet Valve Open button (SETUP main tab […]

Intensifier Breakdown

  • Manuals
  • Parts Lists

Intensifier Breakdown – Hypertherm This breakdown is for Hypertherm HyPrecision 30 series intensifier.

abrasive (garnet) hose routing

  • Service

Improper garnet hose routing can cause flow issues, see the procedure detailed below for proper garnet hose routing. When finished the garnet hose should follow a straight direct path as shown, any excess hose along the path can allow garnet to build up and cause a blockage. 1. From the abrasive regulator route the hose […]

BALLAST TANK WATER LEVEL SENSOR

  • Service

If you are experiencing issues with dirty water affecting the functionality of the proximity sensor that monitors the water level of the ballast tank, please follow the procedure below. To remedy this, an adjustment can be made so that it stops the water before it gets to the sensor, this should help keep mud from […]

saberjet xp – hypertherm communication

  • Service

Setup the IP Address for Hypertherm communication to the Saberjet XP If the ip address is not set correctly, you will get an alarm 1058 Hypertherm-No Communication