Alphacam Missing machine tabs

  • Programming
  • Software Support

This will show you how to re-populate the Park Industries Tool Bars in Alphacam. This typically happens after a Windows update has been installed. Alphacam version 2021 and older Uncheck the 1_PIToolbars option and click OK. Alphacam version 2022 Click Miscellaneous Tab and then uncheck 1_PIToolbars.

SL Laser Easy Sync and cable

How to setup the Easy Sync and communication cable to properly communicate from the IPC to the SL Laser. Install the included Driver CD before you plug in the USB device. SL Teacher will show a new COM port on Tab 9. After teaching the SL LASER, change to COM port setting in the AutoSL.txt […]

Optimus blade to nozzle verification

  • Service

The Blade/Nozzle TCP Verification procedure is done to improve the blade to waterjet transition. This procedure should be performed after any blade change, after removing or replacing the waterjet cutting head, or if the blade to waterjet transition needs to be improved. before making any changes to robodk, take screen shots of all values. after […]

coalescing Element replacement

  • Service

Procedure for performing regular scheduled maintenance on the COALESCING filter element. To access the filter media turn the collar clockwise to loosen the outer bowl protective cover. Remove cover and set aside. Unscrew the baffle which holds the filter element and dispose of the old element. Do NOT attempt to clean or re-use the old […]

bleed down valve repair-video

  • Service

Video shows how to service the bleed down valve inside the intensifier. Make sure to bleed off all pressure before working on intensifier!

waterjet on/off valve-video

This video will show you how to replace seals, needle and seat on the on/off valve for water jet cutting head. On/Off, Off/On, Off On

Correcting leaks at hp connections

  • Service

This document illustrates the steps required to inspect and repair water leaking from the weep holes on the HP line blocks on the attenuator or junction points. It also indicates the proper way to assemble the gland to ensure a leak free seal. Make sure the pressure is bled from the HP lines before disassembling […]

Ghosting Saber, Saberjet & Optimus

  • Service

This guide will show you how to ghost and reset the PC back to original parameters. Doing this will erase all data on your PC. warning: this process will erase all data on your pc. if possible backup information first! ghosting process will take about 15 minutes.

Water Union Replacement

  • Service

This guide will show how to replace the water union for the TITAN 2K & 3K series. lift cylinder straight up to remove, use caution so not to disturb draw bar sensor water union has reverse threads!

Spindle reset-video

  • Service

This guide will walk you through what you will need to do to reset your spindle and make sure it is in good operating condition. Use this video for Titan 1K and 2K models Use this video for 3K and 4K models.